HIMEL Product
Артикулы: HDB9PLEA40C10L, HDB9PLEA40C10S, HDB9PLEA40C16L, HDB9PLEA40C16S, HDB9PLEA40C20L
Final Distribution > 9 Series RCBO
Цена
Цена по запросу
Уточним стоимость в коммерческом предложении.
- SKU
- 28
- Фото
- 1
- Документы
- 0
- В наличии
- 0
SKU и артикулы
28 позиций
| SKU | Артикулы | Модификация | Наличие | Цена | КП |
|---|---|---|---|---|---|
| HDB9PLEA40C10L |
Производитель: HDB9PLEA40C10L
Поставщик: HDB9PLEA40C10L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 10A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C10S |
Производитель: HDB9PLEA40C10S
Поставщик: HDB9PLEA40C10S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 10A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C16L |
Производитель: HDB9PLEA40C16L
Поставщик: HDB9PLEA40C16L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 16A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C16S |
Производитель: HDB9PLEA40C16S
Поставщик: HDB9PLEA40C16S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 16A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C20L |
Производитель: HDB9PLEA40C20L
Поставщик: HDB9PLEA40C20L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 20A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C20S |
Производитель: HDB9PLEA40C20S
Поставщик: HDB9PLEA40C20S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 20A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C25L |
Производитель: HDB9PLEA40C25L
Поставщик: HDB9PLEA40C25L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 25A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C25S |
Производитель: HDB9PLEA40C25S
Поставщик: HDB9PLEA40C25S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 25A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C32L |
Производитель: HDB9PLEA40C32L
Поставщик: HDB9PLEA40C32L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 32A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C32S |
Производитель: HDB9PLEA40C32S
Поставщик: HDB9PLEA40C32S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 32A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C40L |
Производитель: HDB9PLEA40C40L
Поставщик: HDB9PLEA40C40L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 40A 10mA | Под заказ | По запросу | |
| HDB9PLEA40C40S |
Производитель: HDB9PLEA40C40S
Поставщик: HDB9PLEA40C40S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 40A 30mA | Под заказ | По запросу | |
| HDB9PLEA40C6L |
Производитель: HDB9PLEA40C6L
Поставщик: HDB9PLEA40C6L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA - 1P+N - C - 6A - 10mA | Под заказ | По запросу | |
| HDB9PLEA40C6S |
Производитель: HDB9PLEA40C6S
Поставщик: HDB9PLEA40C6S
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 6A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C10L |
Производитель: HDB9PLEN40C10L
Поставщик: HDB9PLEN40C10L
|
Residual Current Operated Circuit Breaker HDB9PLEA-40 4.5kA 1P+N C 10A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C10S |
Производитель: HDB9PLEN40C10S
Поставщик: HDB9PLEN40C10S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 10A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C16L |
Производитель: HDB9PLEN40C16L
Поставщик: HDB9PLEN40C16L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 16A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C16S |
Производитель: HDB9PLEN40C16S
Поставщик: HDB9PLEN40C16S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 16A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C20L |
Производитель: HDB9PLEN40C20L
Поставщик: HDB9PLEN40C20L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 20A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C20S |
Производитель: HDB9PLEN40C20S
Поставщик: HDB9PLEN40C20S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 20A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C25L |
Производитель: HDB9PLEN40C25L
Поставщик: HDB9PLEN40C25L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 25A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C25S |
Производитель: HDB9PLEN40C25S
Поставщик: HDB9PLEN40C25S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 25A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C32L |
Производитель: HDB9PLEN40C32L
Поставщик: HDB9PLEN40C32L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 32A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C32S |
Производитель: HDB9PLEN40C32S
Поставщик: HDB9PLEN40C32S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 32A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C40L |
Производитель: HDB9PLEN40C40L
Поставщик: HDB9PLEN40C40L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 40A 10mA | Под заказ | По запросу | |
| HDB9PLEN40C40S |
Производитель: HDB9PLEN40C40S
Поставщик: HDB9PLEN40C40S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA 1P+N C 40A 30mA | Под заказ | По запросу | |
| HDB9PLEN40C6L |
Производитель: HDB9PLEN40C6L
Поставщик: HDB9PLEN40C6L
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA - 1P+N - C - 6A - 10mA | Под заказ | По запросу | |
| HDB9PLEN40C6S |
Производитель: HDB9PLEN40C6S
Поставщик: HDB9PLEN40C6S
|
Residual Current Operated Circuit Breaker HDB9PLEN-40 6kA - 1P+N - C - 6A - 30mA | Под заказ | По запросу |
Характеристики
Товар и SKU
ATS_CURVE_CODE
- Curve code
- C
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N
ATS_RATED_CURRENT
- [In] rated current
- 6.0 A | 10.0 A | 16.0 A | 20.0 A | 25.0 A | 32.0 A | 40.0 A
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA | 30.0 mA
Сравнение SKU
| SKU | Ambient air temperature for operation | Breaking capacity | Cable entry | Clamping connection capacity | Connections - terminals | Curve code | Depth | Device application |
|---|---|---|---|---|---|---|---|---|
| HDB9PLEA40C10L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C10S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C16L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C16S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C20L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C20S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C25L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C25S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C32L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C32S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C40L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C40S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C6L | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEA40C6S | -25…70 °C | | 4.5 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C10L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C10S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C16L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C16S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C20L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C20S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C25L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C25S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C32L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C32S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C40L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C40S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C6L | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
| HDB9PLEN40C6S | -25…70 °C | | 6.0 kA | | Top | | <= 25 mm² | | Forked type tag connectors | | C | | 75.2 mm | | Isolation | Control | |
Все характеристики по каждому SKU
HDB9PLEA40C10L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C10S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C16L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C16S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C20L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C20S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C25L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C25S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C32L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C32S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C40L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C40S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C6L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEA40C6S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
HDB9PLEN40C10L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C10S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C16L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C16S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C20L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C20S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C25L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C25S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C32L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C32S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C40L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C40S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C6L
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 10.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Offer Sustainability
- Sustainable packaging
- No |
HDB9PLEN40C6S
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -25…70 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 6.0 kA |
ATS_CERTIFICATIONS
- Product certifications
- CE | RoHS | TÜV | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 75.2 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 100.5 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP20 |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6.0 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 500 V |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50...60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30.0 mA |
ATS_WIDTH
- Width
- 35.3 mm |
Complementary
- Cable entry
- Top |
- Clamping connection capacity
- <= 25 mm² |
- Connections - terminals
- Forked type tag connectors |
- Electrical durability
- 10000 cycles |
- Magnetic tripping limit
- 5...10 x In |
- Mechanical durability
- 20000 cycles |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection | Residual current breaker with overcurrent protection (RCBO) |
- Suitability for isolation
- Yes |
- Tightening torque
- 2…3 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4.0 kV |
Environment
- Standards
- IEC 61009-1 |
- Tropicalisation
- 2 |
Main
- Range of product
- HDB9PLE |
Документы
Руководства, сертификаты и материалы производителя
Сертификаты
- PDF HDB9PLEN CB 002484 2019 02 Certificate EN / 316.1 КБ Скачать
- PDF HDB9PLEN CE 50391664 2017 10 Certificate EN / 283.2 КБ Скачать
- PDF HDB9PLEN TUV R50391661 2017 10 Certificate EN / 589.4 КБ Скачать
- PDF HDB9PLEN CB 002484 2019 02 Certificate EN / 316.1 КБ Скачать
- PDF HDB9PLEN CE 50391664 2017 10 Certificate EN / 283.2 КБ Скачать
- PDF HDB9PLEN TUV R50391661 2017 10 Certificate EN / 589.4 КБ Скачать