HIMEL Product
Артикулы: HDB3WPLEY63C10, HDB3WPLEY63C16, HDB3WPLEY63C20, HDB3WPLEY63C25, HDB3WPLEY63C32
Final Distribution > 3 Series RCBO
Цена
Цена по запросу
Уточним стоимость в коммерческом предложении.
- SKU
- 18
- Фото
- 1
- Документы
- 0
- В наличии
- 0
SKU и артикулы
18 позиций
| SKU | Артикулы | Модификация | Наличие | Цена | КП |
|---|---|---|---|---|---|
| HDB3WPLEY63C10 |
Производитель: HDB3WPLEY63C10
Поставщик: HDB3WPLEY63C10
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 10 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C16 |
Производитель: HDB3WPLEY63C16
Поставщик: HDB3WPLEY63C16
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 16 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C20 |
Производитель: HDB3WPLEY63C20
Поставщик: HDB3WPLEY63C20
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 20 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C25 |
Производитель: HDB3WPLEY63C25
Поставщик: HDB3WPLEY63C25
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 25 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C32 |
Производитель: HDB3WPLEY63C32
Поставщик: HDB3WPLEY63C32
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 32 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C40 |
Производитель: HDB3WPLEY63C40
Поставщик: HDB3WPLEY63C40
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 40 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C50 |
Производитель: HDB3WPLEY63C50
Поставщик: HDB3WPLEY63C50
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 50 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C6 |
Производитель: HDB3WPLEY63C6
Поставщик: HDB3WPLEY63C6
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 6 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63C63 |
Производитель: HDB3WPLEY63C63
Поставщик: HDB3WPLEY63C63
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, C curve, 63 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D10 |
Производитель: HDB3WPLEY63D10
Поставщик: HDB3WPLEY63D10
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 10 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D16 |
Производитель: HDB3WPLEY63D16
Поставщик: HDB3WPLEY63D16
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 16 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D20 |
Производитель: HDB3WPLEY63D20
Поставщик: HDB3WPLEY63D20
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 20 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D25 |
Производитель: HDB3WPLEY63D25
Поставщик: HDB3WPLEY63D25
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 25 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D32 |
Производитель: HDB3WPLEY63D32
Поставщик: HDB3WPLEY63D32
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 32 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D40 |
Производитель: HDB3WPLEY63D40
Поставщик: HDB3WPLEY63D40
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 40 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D50 |
Производитель: HDB3WPLEY63D50
Поставщик: HDB3WPLEY63D50
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 50 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D6 |
Производитель: HDB3WPLEY63D6
Поставщик: HDB3WPLEY63D6
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 6 A, 30 mA without indicator | Под заказ | По запросу | |
| HDB3WPLEY63D63 |
Производитель: HDB3WPLEY63D63
Поставщик: HDB3WPLEY63D63
|
Residual current breaker with overcurrent protection (RCBO), HDB3wPLEY-63, 1P+N, D curve, 63 A, 30 mA without indicator | Под заказ | По запросу |
Характеристики
Товар и SKU
ATS_CURVE_CODE
- Curve code
- C | D
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N
ATS_RATED_CURRENT
- [In] rated current
- 6 A | 10 A | 16 A | 20 A | 25 A | 32 A | 40 A | 50 A | 63 A
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA
Сравнение SKU
| SKU | Ambient air temperature for operation | Ambient air temperature for storage | Breaking capacity | Clamping connection capacity | Connections - terminals | Curve code | Depth | Device application |
|---|---|---|---|---|---|---|---|---|
| HDB3WPLEY63C10 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C16 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C20 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C25 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C32 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C40 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C50 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C6 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63C63 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | C | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D10 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D16 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D20 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D25 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D32 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D40 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D50 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D6 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
| HDB3WPLEY63D63 | -20…60 °C | | -40…70 °C | | 4.5 kA | | 25 mm² | | Tunnel type terminals | | D | | 69 mm | | Isolation | Control | |
Все характеристики по каждому SKU
HDB3WPLEY63C10
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C16
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C20
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C25
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C32
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C40
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C50
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 50 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C6
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63C63
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- C |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 63 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D10
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 10 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D16
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 16 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D20
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 20 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D25
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 25 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D32
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 32 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D40
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 40 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D50
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 50 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D6
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 6 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
HDB3WPLEY63D63
ATS_AMBIANT_AIR_TEMPERATURE
- Ambient air temperature for operation
- -20…60 °C |
ATS_BREAKING_CAPACITY
- Breaking capacity
- 4.5 kA |
ATS_CERTIFICATIONS
- Product certifications
- TÜV | CE | CB |
ATS_CURVE_CODE
- Curve code
- D |
ATS_DEPTH
- Depth
- 69 mm |
ATS_DEVICE_APPLICATION
- Device application
- Isolation | Control |
ATS_HEIGHT
- Height
- 80 mm |
ATS_IP_PROTECTION
- IP degree of protection
- IP40 distribution box | IP20 direct mounting |
ATS_MOUNTING_SUPPORT
- Mounting support
- 35 mm DIN rail |
ATS_OPERATING_ALTITUDE
- Operating altitude
- 2000 m |
ATS_POLES_DESCRIPTION
- Poles description
- 1P + N |
ATS_PRODUCT_OR_COMPONENT_TYPE
- Product or component type
- Residual current breaker with overcurrent protection (RCBO) |
ATS_RATED_CURRENT
- [In] rated current
- 63 A |
ATS_RATED_INSULATION_VOLTAGE
- [Ui] rated insulation voltage
- 250 V between phase and ground | 500 V between phases |
ATS_RATED_OPERATIONAL_VOLTAGE
- [Ue] rated operational voltage
- 240 V AC 50/60 Hz |
ATS_RESIDUAL_CURRENT
- Residual current
- 30 mA |
ATS_STORAGE_AIR_TEMPERATURE
- Ambient air temperature for storage
- -40…70 °C |
ATS_WIDTH
- Width
- 35.4 mm |
Complementary
- Clamping connection capacity
- 25 mm² |
- Connections - terminals
- Tunnel type terminals |
- Electrical durability
- 4000 cycles |
- Enclosure type
- No enclosure |
- Environmental characteristic
- High temperature: category 2 28 cycles conforming to IEC 60068-2 | Humidity resistant: category 2 28 cycles conforming to IEC 60068-2 |
- Local signalling
- Without light indicator |
- Location of connection
- Top |
- Mechanical durability
- 10000 cycles |
- Overvoltage protection
- Without |
- Protection type
- Short-circuit protection | Overload protection | Earth-leakage protection |
- Reset
- Manual reset earth leakage | Manual reset overcurrent |
- Suitability for isolation
- Yes |
- Tightening torque
- 2 N.m |
- Trip unit technology
- Thermal-magnetic |
- [Uimp] rated impulse withstand voltage
- 4 kV |
Environment
- Dielectric test voltage
- 2 kV 50/60 Hz 1 min |
- Electrical shock protection class
- Class II |
- Pollution degree
- 2 |
- Relative humidity
- 90…96 % at 55 °C | 95…100 % at 25 °C |
- Shock resistance
- 30 gn (duration = 11 ms) for 3 shocks conforming to EN/IEC 60068-2-6 |
- Standards
- IEC 61009-1 |
Main
- Range of product
- HDB3wPLEY |
Offer Sustainability
- Sustainable packaging
- No |
Документы
Руководства, сертификаты и материалы производителя