EXW3 Air Circuit Breaker
Артикулы: HUYU-EXW3
Под заказ
Цена по запросу
Официальная карточка HUYU Electric. Источник: https://huyuelectric.com/product/exw3/
Цена
Цена по запросу
Уточним стоимость в коммерческом предложении.
- SKU
- 1
- Фото
- 21
- Документы
- 0
- В наличии
- 0
Описание
Официальная карточка HUYU Electric. Источник: https://huyuelectric.com/product/exw3/
SKU и артикулы
1 позиций
| SKU | Артикулы | Модификация | Наличие | Цена | КП |
|---|---|---|---|---|---|
| HUYU-EXW3 |
Производитель: EXW3
Поставщик: huyu-exw3
|
EXW3 Air Circuit Breaker | Под заказ | По запросу |
Характеристики
Товар и SKU
Сравнение SKU
| SKU | Air Blast ACB | Best For | Controller type | Current Rating | Electrical life | Feature | Installation method | Item |
|---|---|---|---|---|---|---|---|---|
| HUYU-EXW3 | Uses a blast of compressed air to literally blow the arc out. | High-voltage systems and specialized industrial plants. | Main LV Panels | High Voltage Substations | Branch Circuit Protection | — | M / H | M / H | M / H | M / H | M / H | M / H | 630A to 6300A | Up to 3000A+ | 16A to 1600A | Times | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ACB (Air Circuit Breaker) | VCB (Vacuum Circuit Breaker) | MCCB (Molded Case Circuit Breaker) | — | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Unit | EXW3-1000 | EXW3-1600 | EXW3-2000 | EXW3-3200 | EXW3-4000 | EXW3-6300 |
Все характеристики по каждому SKU
HUYU-EXW3
Основные
- Air Blast ACB
- Uses a blast of compressed air to literally blow the arc out. | High-voltage systems and specialized industrial plants.
- Best For
- Main LV Panels | High Voltage Substations | Branch Circuit Protection
- Controller type
- — | M / H | M / H | M / H | M / H | M / H | M / H
- Current Rating
- 630A to 6300A | Up to 3000A+ | 16A to 1600A
- Electrical life
- Times | 2000 | 2000 | 2000 | 2000 | 2000 | 2000
- Feature
- ACB (Air Circuit Breaker) | VCB (Vacuum Circuit Breaker) | MCCB (Molded Case Circuit Breaker)
- Installation method
- — | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable
- Item
- Unit | EXW3-1000 | EXW3-1600 | EXW3-2000 | EXW3-3200 | EXW3-4000 | EXW3-6300
- Magnetic Blast ACB
- Uses a magnetic field to “pull” the arc into the extinguishing chamber. | High-speed interruption requirements.
- Maintenance
- Easy to maintain/repair | Difficult/Unit replacement | Minimal/Replace if broken
- Mechanical life
- Times | 10000 | 10000 | 10000 | 10000 | 10000 | 10000
- Medium
- Atmospheric Air | Vacuum | Air (Sealed)
- Number of poles
- P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P
- Plain Air ACB
- Uses natural air flow and arc chutes to extinguish the arc. | Standard Low-Voltage distribution.
- Rated current (In)
- A | 1000 | 1600 | 2000 | 3200 | 4000 | 6300
- Rated frequency
- Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60
- Rated insulation voltage (Ui)
- V | AC1000 | AC1000 | AC1000 | AC1000 | AC1000 | AC1000
- Rated operational voltage (Ue)
- V | AC400/690 | AC400/690 | AC400/690 | AC400/690 | AC400/690 | AC400/690
- Rated short-circuit breaking (Icu)
- kA | 50/35 | 50/35 | 85/50 | 85/100 | 85/100 | 120/85
- Rated short-time withstand current
- kA/1s | 50 | 65 | 80 | 100 | 100 | 100
- Source heading
- The Role of ACB in Low-Voltage Distribution Systems
- Type
- Description | Primary Use Case
- Voltage Range
- Up to 1kV (Low Voltage) | 11kV – 33kV (Medium/High) | Up to 1kV