EXW3 Air Circuit Breaker

Артикулы: HUYU-EXW3

Под заказ Цена по запросу

Официальная карточка HUYU Electric. Источник: https://huyuelectric.com/product/exw3/

Цена Цена по запросу Уточним стоимость в коммерческом предложении.
SKU
1
Фото
21
Документы
0
В наличии
0

Описание

Официальная карточка HUYU Electric. Источник: https://huyuelectric.com/product/exw3/

SKU и артикулы

1 позиций

SKU Артикулы Модификация Наличие Цена КП
HUYU-EXW3
Производитель: EXW3
Поставщик: huyu-exw3
EXW3 Air Circuit Breaker Под заказ По запросу

Характеристики

Товар и SKU

Сравнение SKU

SKU Air Blast ACB Best For Controller type Current Rating Electrical life Feature Installation method Item
HUYU-EXW3 Uses a blast of compressed air to literally blow the arc out. | High-voltage systems and specialized industrial plants. Main LV Panels | High Voltage Substations | Branch Circuit Protection — | M / H | M / H | M / H | M / H | M / H | M / H 630A to 6300A | Up to 3000A+ | 16A to 1600A Times | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 ACB (Air Circuit Breaker) | VCB (Vacuum Circuit Breaker) | MCCB (Molded Case Circuit Breaker) — | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable Unit | EXW3-1000 | EXW3-1600 | EXW3-2000 | EXW3-3200 | EXW3-4000 | EXW3-6300
Все характеристики по каждому SKU

HUYU-EXW3

Основные

Air Blast ACB
Uses a blast of compressed air to literally blow the arc out. | High-voltage systems and specialized industrial plants.
Best For
Main LV Panels | High Voltage Substations | Branch Circuit Protection
Controller type
— | M / H | M / H | M / H | M / H | M / H | M / H
Current Rating
630A to 6300A | Up to 3000A+ | 16A to 1600A
Electrical life
Times | 2000 | 2000 | 2000 | 2000 | 2000 | 2000
Feature
ACB (Air Circuit Breaker) | VCB (Vacuum Circuit Breaker) | MCCB (Molded Case Circuit Breaker)
Installation method
— | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable | Fixed / Withdrawable
Item
Unit | EXW3-1000 | EXW3-1600 | EXW3-2000 | EXW3-3200 | EXW3-4000 | EXW3-6300
Magnetic Blast ACB
Uses a magnetic field to “pull” the arc into the extinguishing chamber. | High-speed interruption requirements.
Maintenance
Easy to maintain/repair | Difficult/Unit replacement | Minimal/Replace if broken
Mechanical life
Times | 10000 | 10000 | 10000 | 10000 | 10000 | 10000
Medium
Atmospheric Air | Vacuum | Air (Sealed)
Number of poles
P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P | 3P / 4P
Plain Air ACB
Uses natural air flow and arc chutes to extinguish the arc. | Standard Low-Voltage distribution.
Rated current (In)
A | 1000 | 1600 | 2000 | 3200 | 4000 | 6300
Rated frequency
Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60
Rated insulation voltage (Ui)
V | AC1000 | AC1000 | AC1000 | AC1000 | AC1000 | AC1000
Rated operational voltage (Ue)
V | AC400/690 | AC400/690 | AC400/690 | AC400/690 | AC400/690 | AC400/690
Rated short-circuit breaking (Icu)
kA | 50/35 | 50/35 | 85/50 | 85/100 | 85/100 | 120/85
Rated short-time withstand current
kA/1s | 50 | 65 | 80 | 100 | 100 | 100
Source heading
The Role of ACB in Low-Voltage Distribution Systems
Type
Description | Primary Use Case
Voltage Range
Up to 1kV (Low Voltage) | 11kV – 33kV (Medium/High) | Up to 1kV